Hargassner Airflow-M
Air-to-water heat pumps
For new homes and renovated buildings. The heat pumps extract heat from the outside air and operate efficiently down to −25 °C.
- Authorised Hargassner dealer
- 5–20 kW, 8 models
- Heating, cooling and hot water
- Hybrid with a biomass boiler

Performance values of the Airflow-M range
Airflow-M heat pumps provide heating in winter and cooling in summer and can operate together with a biomass boiler. The notes state the model and the standard for each value.

- SCOP of up to
- 4.76¹kWh of heat per season for every kWh of electricity
- Energy class up to
- A+++¹at 35 °C flow temperature
- Efficient operation down to
- −25 °Coutside temperature
- Flow temperature up to
- 65 °Cheating water temperature
- Quiet operation, from
- 46 dB(A)²sound power level
¹ Best values in the range at 35 °C flow: SCOP 4.76 (AFM 16) and class A+++ (AFM 14–20), according to EN 14511, average climate. ² Sound power level in normal mode, AFM 9, according to EN 12102.
How an air-to-water heat pump works
Heat extracted from the outside air passes through the outdoor unit and the indoor module and is then distributed in the building.
- 01
Outside air
The energy comes from the outside air. The outdoor unit extracts it efficiently even at −25 °C.
- 02
The monoblock outdoor unit
It houses the full refrigeration circuit: evaporator, compressor, condenser and expansion valve. Three sizes, 5–20 kW.
- 03
BASIC
STYLECOMFORT
COMFORT II
Indoor module variants
The indoor module controls the entire installation: heating, cooling and domestic hot water. There are four variants, depending on the equipment required.
- 04
Heating, cooling and hot water
Heating and cooling as standard, domestic hot water and flow temperatures up to 65 °C.
Four variants that differ only in the indoor module.
The factory equipment ranges from simple control for existing installations (BASIC) to a DHW tank and two heating circuits (COMFORT II).
Choosing a variant in two questions
Once you answer, the variant is highlighted in the list and in the comparison table. The final recommendation is made by an engineer, free of charge.

Airflow-M BASIC
For simple heating control.
- Control of the entire heating system
- Integrated flow sensor
- Continuously controlled high-efficiency pump
- Wall-mounted, also suitable for existing installations

Airflow-M STYLE
Integrated hydraulic components in a compact wall-mounted unit.
- Wall-mounted indoor module
- Bottom hydraulic connections
- Integrated magnetic separator
- Integrated electric heater

Airflow-M COMFORT
Compact indoor unit with 250/310 l DHW tank and one direct heating circuit.
- Built-in 250 / 310 l DHW tank
- Small footprint in the plant room
- One direct heating circuit integrated
- Control of the entire heating system
- 7" colour touchscreen

Airflow-M COMFORT II
Built-in DHW tank and two heating circuits, one direct and one mixed.
- Built-in 250 / 310 l DHW tank
- Small footprint in the plant room
- One direct and one mixed heating circuit integrated
- 7" colour touchscreen
Airflow-M variant comparison
The outdoor unit is the same in every variant.
| Feature | Airflow-MBASIC | Airflow-MSTYLE | Airflow-MCOMFORT | Airflow-MCOMFORT II |
|---|---|---|---|---|
| Control of the full heating system | Yes | Yes | Yes | Yes |
| Flow sensor included | Yes | Yes | Yes | Yes |
| High-efficiency variable pump | Yes | Yes | Yes | Yes |
| Magnetic dirt separator integrated | No | Yes | Yes | Yes |
| Electric heater integrated | No | Yes | Yes | Yes |
| Safety group integrated | No | Yes | Yes | Yes |
| Domestic hot water tank integrated | No | No | Yes | Yes |
| 3-way valve integrated | No | No | Yes | Yes |
| Top hydraulic connections | No | No | Yes | Yes |
| Bottom hydraulic connections | No | Yes | No | No |
| 1 direct heating circuit | No | No | Yes | Yes |
| 1 mixed heating circuit | No | No | No | Yes |

Heat pump and biomass boiler in one installation.
Airflow-M can operate as a hybrid system with a biomass boiler. As an authorised Hargassner dealer, we design the entire installation: heat pump, boiler, buffer tank and controls.
- Hybrid function in every Airflow-M variant
- Hargassner pellet (6–330 kW) and wood chip (20 kW – 2.5 MW) boilers
- Free technical consultation for the entire installation
How the project proceeds, in three stages
01
Building details
Floor area, insulation and the existing heating system. By form or by phone, Monday to Friday, 08:00–16:00.
02
Consultation and sizing
We calculate the required output and select the variant: BASIC, STYLE, COMFORT or COMFORT II. The technical consultation is free of charge.
03
Delivery, installation and commissioning
We deliver and install in Austria and Germany, then commission the installation.
Frequently asked questions about heat pumps
We determine the right variant and output for your building.
The heated floor area, how well it is insulated and which fuel you have to hand. The final quote follows the technical assessment.
- Free technical consultation
- Authorised Hargassner dealer
- Delivery and installation in Austria and Germany